Establishing communication with ELICOM electronic scales
How to connect I-Cash to an ELICOM scale
Elicom Electronic has been on the Bulgarian market for 25 years. Its products are familiar to Bulgarian retailers. This article responds to increasingly frequent inquiries from our clients. The operating manual explains how communication with external devices is established. Here is an excerpt.
The scales have several built-in communication protocols, activated by configuring the CASH XX parameter in service mode 1. The transmission speed is set with the T button (the left digit on the display), and the cash register type with the PRT button (the right digit on the display). Communication takes place through CHANNEL 1. Channel 2 is mainly intended for connection to a label printer.
| First digit | Speed [baud] | Second digit | Report |
|---|---|---|---|
| 0 | 4800 | 0 | Electronics |
| Second digit: 0 Protocol: Electronics |
|||
| 1 | 1200 | 1 | Orgtehnika cash register |
| Second digit: 1 Protocol: Orgtehnika cash register |
|||
| 2 | 2400 | 2 | ELKA 752 cash register, Datecs |
| Second digit: 2 Protocol: ELKA 752 cash register, Datecs |
|||
| 3 | 4800 | 3 | Karat cash registers, Daisy Tech AD, BIMCO scales |
| Second digit: 3 Protocol: Karat cash registers, Daisy Tech AD, BIMCO scales |
|||
| 4 | 9600 | 4 | Eltrade cash register |
| Second digit: 4 Protocol: Eltrade cash register |
|||
| 5 | 19200 | 5 | Continuous weight transmission protocol |
| Second digit: 5 Protocol: Continuous weight transmission protocol |
|||
| 6 | 38400 | 6 | Connection to PC, PRN |
| Second digit: 6 Protocol: Connection to PC, PRN |
|||
| 7 | 4800 | 7 | Angel, CAS and DIBAL scales |
| Second digit: 7 Protocol: Angel, CAS and DIBAL scales |
|||
For example, CASH 43 means a speed of 9600 for a Daisy cash register. When connected to a cash register, the scale responds to weight requests through the interface, but can also transmit the weight of a balanced load…
Author's note: The same protocol is used to communicate with ICASH. A connection via an RS232 cable is required, with an RS232-to-USB adapter and appropriate drivers if needed. The cable must be purchased from the manufacturer.
– – –
Programming an S200 scale:
Selecting the menu button
Navigating with the button <0> to the SPEED menu
Editing: press the red power button to enter edit mode and use <0> the speeds are changed. In our case, 9600
Save: confirm using the red power button
Navigate using the button <0> to the Firmware menu
Editing: press the red power button to enter edit mode and use <0> switches protocols. In our case, 3
Save: confirm using the red power button